Installing a Plug-on Digicom
1. A digicom type DC54 or DC58 can be fitted in the base of the TS700 main panel. The unit
should be fitted in accordance with the i nstallati on instruc tions supplied with it and
connected to JP3.
2. The alarm channels for the plug-on digicom a re programmed as required (page 16). It will
be necessary to fit a programmed NVM in the digicom or to program it in accordance with
the instructions supplied with the unit.
Installing a stand-alone Digicom or RedCARE
A stand-alone digital communicator, Red CARE STU or Paknet interface card can be connected
tothesystemtotrans ferpanelalarmstatusinformationtoa dedicatedalarmreceivingcentre.The
control panel has the following conne ctions (Figure 6) for a digicom etc.
1 to 8 - These are the programmabledigicom outputs. They are norm ally at+ 12V
and switch to 0V when active.
+DC POWER - This provides a permanent +12V power to the digicom. The output is
un-fused a nd therefore should only be used if the digicom is fitted inside
the control panel.
LINE FLT - When this input is switched to +12V a telephone line fault condition will be
generated.
REM RESET - Ifth e system is programmed for“Engineer Reset”,t hen after a fullalarm the
system wi llrequireresetting, norma llythis is done bythe e ngineer orcoded
remote reset. Applying a -ve to th is input terminal will cause the system to
reset after a full alarm. This input could be connected to the “Control”
output on a RedCARE STU s o that the Alarm Receiving Centre can poll the
STU and thus reset the panel.
10
System Ins tallation TS700 Installation Manual
Control
Panel
3GSTU
1
1
+DC POWER
Program
As:-
Open (08)
Alarm (05)
PA (06)
Fire (07)
LINE FLT
AUX 0V
2
2
3
3
4
4
5
TB1
Channel Inputs are
Progr ammed as
Positive Removed
TB2
TB3
TB4
Control
Line
Fault RPS
5
6
6
7
7
0V
NO NO NONC NC NC
8
8
C CC
A+ A+ A+ A+ V+
Figure 6. 3GSTU RedCAR E Connections