System Timers
The system timers are as follows:
00 ACPO Delay
For ACPO requirements this timer normally set
to 90 seconds. If during the entry procedure
the user deviates from the entry route and
generates an alarm, the communication of
the alarm signal to the central station is
delayed by this timer. This timer has a working
range of 000-199 seconds.
01 No of Re-Arms
At the end of the bell duration time the system
re-armsall circuitsthatarehealthy.Circuitsthat
are still in an alarm are isolated until they
change to a healthy condition. This counter
controls the number of times that a "circuit" will
re-arm before itis locked out of thesystem.This
counter has a working range of 000-199.
02 Settle Time
When setting the system by “Final Exit” or “Exit
Terminator”,detectorsthatare onthe exitroute
sometimes take 3-4 seconds to settle after
activation.The delayprogrammedinthis timer
isused toallowthese detectors to settle before
the system or area is set. This timer has a
working range of 000-199 seconds.
03 Part Set Comms Delay
When the system is part-set the
communication of an alarm signal to the
central station can be delayed by the value
set in this timer. If the timer is set to 199 the
part-set communications are disabled. This
timerhasaworkingrangeof000-199seconds.
04 Exit Time
This timer sets the delay between the user
initiating the exit procedure and the system (or
area) actually setting. If during the exit time an
“ExitTerminator”circuitisactivatedthe exittime
is cancelled and the system sets immediately.
This timer has a working range of 000-199
seconds.
05 Entry Time
When thesystem issetorpart-set,andtheentry
procedure is initiated, the entry timer starts to
count down. If a valid user passcode has not
been entered when the timer reaches zero,
the internal sounders are activated and the
“2nd Entry. . .” timer is started. This timer has a
working range of 000-199 seconds.
06 Bell Duration
This controls the duration of the external
bell/sounder. If the timer is set to 199 the bell
output is continuous. This timer has a working
range of 000-199 minutes.
Program circuits
Enter CCT No.>--
CCT 04 NIGHT
CCT 04 F.EXIT
>* * * * * * * *
CCT 04 F.EXIT
>* * * * * * * C
Enter circuit type:
= Not Used
= Night
= 24hr
= PA Silent
Circuit No.
Attributes
Circuit Type
4
0
1
2
3
ENT
Enter circuit No.
e.g. 04
= Final Exit
= Exit Terminator
= Key Point
= PSU-Battery
7
8
9
A
ENT
e.g. 7 for Final Exit
Select attributes:
= ccessA
= KnockD
= estT
1
2
3
= esetR
= laggedF
= ntryE
5
6
7
ENT
e.g. 6 for chime
= PA Audible
4
= PSU-Fuse
B
= Fire
5
= PSU-Power
C
= Auxiliary
6
= mitO4 = himeC8
Engineers menu 1
Select Options :-
StarburstLCD
LED
E1 -
ENGR 1 -
CT.--
CCT NO.--
NITE
NIGHT
04
FE
04
F.EXIT
04
FE
CHI
04
F.EXIT
CHIME
Program Circuits Flowchart
TS900 Installation Manual Engineer's Menu 1