TECHNICAL BULLETIN
No. TSD401/001/3/95
TSD401 CONTROL PANEL
Symptom
When the TSD401 is triggered into an alarm condition, the dialler is activated and the unit will
proceed to dial the first telephone number. If a valid passcode is entered whilst the unit is
dialling, there is a remote possibility that the dialler may subsequently dial incorrectly.
Solution
To check whether this has ever occurred, play-back any of the recorded messages and if a
continuous tone is superimposed over the original message, the dialler may not dial correctly.
If this is the case, proceed as follows:
1. Remove all power from the system (mains and battery), then re-apply all power.
2. Select 'Speech Dialler' programming and re-record all messages.
3. Re-program all stored telephone numbers to 'Pulse' dial (see page 17 of the User Manual)
and exit 'Speech Dialler' programming.
However, if the message does not have a continuous tone superimposed over it, simply
perform step 3 of the above action.
All TSD401's after serial number
'97F12100'
will not require the above action.