Re-arm Options 1 re-arms (1)
When an alarm occurs, the internal and external sounders are
operated for the length of the bell duration. At the end of this
time the alarm is silenced and the all zones are re-armed. Any
zones that are active will be automatically isolated until they
return to their healthy state. If an alarm occurs from the same
zone it will cause the internal and external sounders to operate
again, at the end of the alarm the zone is "Locked-out" and
prevented from generating another alarm. All other healthy
zones will re-arm and will only be "Locked-out" when they have
caused another alarm.
3 Re-arms (3)
Operates as above, but zones are only "Locked-out" after the
system has re-armed 3 times.
Key Switch Options AWAY (A)
When key switch zone is opened the exit procedure for AWAY set
will start and when exit timer has expired or the Final Exit zone is
operated the system will be full set. When the zone is closed the
system will unset.
HOME (H)
When the key switch zone is opened the exit timer will start and
when the timer has expired the system will be part-set. When the
zone is closed the system will unset.
RST Output Options Switched 12V (S)
This may be connected to the "Latch" input on latching
detection devices (such as PIR's).
Detector Reset (D)
This may be used as the 0V connection to detectors that require
the power to be removed to reset them (such as Smoke
detectors and Vibration Sensors).
Part-set Final Exit
Options
Final Exit (E)
When the system is part-set (HOME) the Final Exit zone will start
the entry procedure if activated.
Night (N)
When the system is part-set (HOME) the Final Exit zone will cause
a full alarm if activated (i.e., the Final Exit becomes a Night zone
when the system is part-set).
Programming TSD402 Installation Manual