The TSD402 incorporates a 3 button set facility which simplifies the setting and part-setting
of the system for user. When the user wishes to full set the system, they simply enter the first
2 digits of their passcode followed by the AWAY key. To part-set the system, they simply
enter the first 2 digits of their passcode followed by the HOME key. When unsetting the
system the user must enter all 4 digits of the passcode.
Speech Dialler Operation
The speech dialler may be configured by the engineer to trigger on FIRE, P.A. or ALARM
activations for both the Away set and Home set. In addition to alarm triggers provided
internally from the control panel, there are 3 auxiliary inputs which may be used by other
devices to trigger the speech dialler independently from that of the control panel.
Telephone
Numbers
- The TSD402 stores up to three different telephone numbers. Each
number may be up to 16 digits long and are simply
programmed using the text display and keypad on the unit. The
unit is compatible with most PABX systems that require a pause
or wait for secondary dial tone. Note: The Emergency Service
numbers (999 &112) cannot be programmed into the unit.
Messages - The TSD402 has a built-in microphone and speaker so that
phrases can be recorded and replayed directly from the unit. A
message is formed by combining a common phrase (0) and
one of the alarm phrases (F, P or A). When the out-going call is
answered the unit plays the common phrase (0) and one of the
three alarm phrases F, P or A. Phrase 0 states the name and
address of the user and phrases F, P and A relate to the alarm
type (FIRE ,PA, ALARM). There is 60 seconds of recording time
available for phrases and each phrase can be any length as
long as the total does not exceed 60 seconds. For example, the
"Common Phrase" may be 12 seconds, "Phrase F" 5 seconds,
"Phrase P" 8 seconds and "Phrase A" 7 seconds.
Reporting Options - Each alarm type (F, P or A) may be programmed to report only
to selected telephone numbers. For example the Fire activation
may be programmed to report to all three telephone numbers,
whereas the Alarm activation may be programmed to report
only to telephone numbers 1 and 3 etc.
Call
Acknowledgement
- When the call is answered, the message is played. At the end of
the message the unit sends an audible "bleep" which must be
answered within 2 seconds using the tone generated by pressing
the number [8] button on a standard telephone. On hearing the
[8] tone the unit immediately sends a second "bleep" which must
be answered in the same way. If successful, a multi-tone
confirmation signal is then heard, if not then the message is
Overview TSD402 Installation Manual
4